PPolySim OS
Controls & Robotics Pack · Multi-Solver

Servo Tuning Kit

Motor, PID, Bode. This multi-solver chains 3 solvers into a single guided workflow — run each step in order and carry the result forward.

Workflow steps
  1. dc-motor
  2. pid-control
  3. bode-plot
or unlock everything with Pro →
DC MotorLive

Controls

Presets

A DC motor speeds up until back-EMF balances the applied voltage, giving a first-order step response. Its steady speed drops linearly with load along the speed-torque line: maximum speed at no load, maximum (stall) torque at zero speed. The green dot is the operating point where motor and load torque match.

▶ Run in Python

Data Inspector

No-load speed240 rad/s
Steady speed224 rad/s
Stall torque0.30 N·m
Current draw0.4 A
Reading this result: Light load: speed stays close to the no-load value, since only a small back-EMF drop is needed to supply the torque.

Governing equation

Runs locally in your browser — free forever. Scale to the cloud when reality gets heavy.

PID ControllerLive

Controls

Presets

A PID controller drives a system to its setpoint using three terms: proportional reacts to the current error, integral eliminates steady-state offset, and derivative damps overshoot. Tuning the three gains trades off speed, overshoot, and stability — the workhorse of industrial control.

▶ Run in Python

Data Inspector

Overshoot0%
Settling time0.00 s
Steady-state error0.000

Governing equation

Reading this result: Balanced gains — proportional for speed, integral to remove offset, derivative to damp overshoot: the textbook well-tuned response.

Runs locally in your browser — free forever. Scale to the cloud when reality gets heavy.

Bode Plot (2nd-Order System)Live

Controls

Presets

A Bode plot shows how a system responds across frequency: gain in decibels on top, phase shift below. This second-order low-pass passes low frequencies and rolls off at −40 dB/decade above its natural frequency. Low damping produces a resonant peak; high damping smooths it away.

▶ Run in Python

Data Inspector

Natural freq1,000 Hz
Damping ζ0.30
Resonant peak+4.8 dB
Roll-off−40 dB/dec

Governing equation

Reading this result: Low damping ζ=0.30 produces a sharp +4.8 dB resonant peak just below fn — great for selectivity, but it rings in the time domain.

Runs locally in your browser — free forever. Scale to the cloud when reality gets heavy.

Need a private, branded version?

We build custom solvers and workflows for labs, firms, agencies, and courses — your parameters, your branding, your data.

Explore Custom Solver Sets →

More in the Controls & Robotics pack

Frequently asked questions

What is the Servo Tuning Kit multi-solver?
Servo Tuning Kit is a guided workflow that chains 3 individual PolySim solvers into one end-to-end analysis, piping each result into the next step.
Is it free to use?
Yes. Every step runs entirely in your browser using real numerics — no install, no account, no cloud cost. Custom or private solver packs are available as a paid service.